Department of Mechanical Engineering
Infrastructure Facility
I. Major Equipments Available
Sl. No. |
Major Equipments Available |
Brief Specification |
Quantity |
---|---|---|---|
1 |
Resistance Furnace (SIC) | Max. Temp.- 13000C, Operating Temp.- 10000C. Specifications-3F 440 Volts, Power rating-6Kw Max. |
1 |
2 |
Computer Controlled Resistance Furnace (SiC) | Max. Temp.- 14000C. Operating Temp.- 13000C Specifications-3F 440 Volts, Power rating-6Kw |
1 |
3 |
Atomic Absorption Spectrometer(VARIAN imported from The Netherlands) | Installation Category II, Pollution degree 2, Safety Class 1(EN 61010-1, Gas supplies C2H2 (65-100kPa and 0-10 L/min), Air (245-455 kPa and 13.5-20 l/min)), N2O (245-455 kPa and 11-16 L/min) , Air Purge, (245-455 kPa and 10 L/min.) Required supply voltage: 100 VAC +10% -5%, Rating 170 VA | 1 |
4 |
Computer Controlled Universal Testing Machine (CUTM) with clip on extensometer | Load Range: 0-50 kN Load Resolution: 1st Range: 0-40% of FS: 1/10000 of nominal load cell connected 2nd Range: 40-100% of FS: 1/4000 of nominal load cell connected Load measuring accuracy: ±1% from 2% to 100% of nominal load of load cells used Max. cross head stroke: 1000 mm (without grips and load cell) Clearance between columns: 450 mm Cross head displacement measurement: 0.1 mm Cross head Speed Range : 0.5 to 500 mm/min Power Supply: Single phase, 230 VAC, 50 Hz | 1 |
5 |
Automatic Micro Hardness Tester | Pick up element: ½” Interline transfer CCD Image Sensor Number of Pixels 795 (H) X 596 (V) Sensing Area 752 (H) X 582 (V) Unit Cell size 8.6 µm (h) X 8.3 µm (V) Sync System: Internal Scanning System 2:1 Interfaced Video Output 1Vp-p 75 ohms (unbalanced) Horizontal Resolution: Composite more than 450 TV lines (Centre) Power Supply DC +10V-15V (DC) Operating Temperature -10°C - +40°C | 1 |
6 |
H-Scan Analyser (for Hydrogen in Molten Aluminium) | Overall Dimensions: 60 cm x 60 cm X 100 cm high (approx) Overall weight: 120 kg Electrical input: 240 V 50 Hz, single phase, 110 V, 50/60 Hz Sample weight: 100 gm Measurement time: 5 min. Range: up to1.99 cm/100g Sensitivity: 0.001/100 gm | 1 |
7 |
Precision Diamond Sectioning Machine (Model Metacut-DCM) | Input Supply: 220 VAC,±10%, 50 Hz Output field Voltage: 210 V DC fixed Operating temperature: 0-45°C Speed Ratio: 1:10 Feed back: Armature feedback Max. speed adjustment: 50-100% of rated speed | 1 |
8 |
Automatic Electrolytic Polishing cum etching machine | Highly regulated switched mode power supply (SMPS) with 110vDC and 24v DC pump control, Digital display for voltage and current. Power Source: 230V AC, 50 Hz, Single phase, AC, Mains Supply | 1 |
9 |
Automatic multi specimen Grinder/Polisher Machine | Motor capacity - 1 HP DC, with DC drive. Supply - 230 V, AC, Single phase. Disc - 200 mm. Polishing load - 150 PSI (Pneumatic). Supplied with sample levelling press. | 1 |
10 |
DSP centric Signal Processing Hardware | No of Channels: 4 ADC Resolution: 24 bit Resolution 51,200 lines & Frame Size up to 131072 Coupling: AC/DC, DIFF/SE, ICP, TEDS Anti-alias Filters: 110 dB protection, all ranges Dynamic Range: 120 dB to 150 dB Input Ranges: 1/2/5/10 V full scale (25 V optional) Input Impedace: 1MOhm to GND, 50 SE shield to GND Max Input Voltage: 80V Peak, 2.5V RmsShield(SE) CMRR: 60 dB (typical), f < 40 kHz Amplitude Accuracy: +/- 0.020 dB (0.2% FS) at 1 kHz for 15°C < T < 40°C Phase Accuracy: 0.05° to 0.5° for DC to 40 kHz Crosstalk between Inputs: < -100 dB Crosstalk between inputs and source: < -90 dB Input noise: 1 V range: 20 nV/Hz, 3 μVrms @ 20 kHz BW 10 V range: 160 nV/Hz, 24 μVrms @ 20 kHz BW THD: 100 dB Overload Detection: Both pre-filter and post-filter Minimum SampleRate: less than 1 Sps Maximum SampleRate: 107.42 kSps Sample rates: 83 steps, down to 1 Hz Maximum useful Frequency: 49 kHz standard Frequency Accuracy: 25 ppm | 4 |
11 |
Accelerometers | Sensitivity: 100mV/g Range: +50g Frequency Range: 1-10kHz 10-32 mounting stud Top Connector Weight: < 4grams Operating Temp range: -55˚C to +125˚C Hermatically sealed | 4 |
12 |
Microphone | ½-inch prepolarized pressure microphone and preamplifier with BNC co-axial connector.TEDS support Frequency response: 3.15 Hz–10 kHz: Weight: < 35 grams | 1 |
13 |
CRDi diesel engine with open ECU | Open ECU: Model Nira i7r (with solenoid injector driver) with programmable ECU software and Calibration cable Data acquisition: Make NI Instrument USA, NI USB-6210, 16-bit, 250kS/s. | 1 |
14 |
5 Gas analyzer | (MRU, Germany Delta 1600 S) | 1 |
15 |
Smoke meter | (MRU, Germany, Optrons 1600) | 1 |
16 |
Digital pressure meter | (MRU, Germany C9557) | 1 |
II. Software’s Available
Sl. No. |
Name |
Version |
Type (System/ Application) |
---|---|---|---|
1 |
Solid Edge, Modelling Software | V19 |
Application |
2 |
ANSYS Academic Teaching | V14.5 |
Application |